Product Features
Medical & ITE safety approvals |
2 MOPP input to output isolation |
DOE Efficiercy Level VI & CoC V5 Tier2(2016) |
Low Leakage current≤100μA |
≤0.075W standby power |
7V to 52V outputs,up to 24W |
Up to 5000m operating altitude |
Interchangeable AC plugs |
Input |
Input Voltage Range:80-264VAC
Frequency Range:47-63Hz
Input Current:0.5A,at 90VAC
Inrush Current:70A max at 240VAC cold start
Touch Leakage Current(max):≤ 100μA at 264VAC
Environmental
Operationg Temperature: 0℃ to 45℃
Storage Temperature:- 20℃ to 60℃
Operating Humidity:10 to 90% RH,non-condensing
Storage Humidity::5 to 90% RH
Operating Altitude:5,000 M
General
Dimensions:90.5(L)×33.5(W)×58.5(H)mm
Weight:170g
MTBF:>100000hrs MIL-HKBK-217 at 25℃
Isolation:4000VAC Input to Output
Safety Approvals | |||||||||||
Safety Agency/Mark | Medical(Meet) | ITE(Meet) | |||||||||
CB | IEC60601-1/IEC60601-1-11 | IEC62368-1 | |||||||||
UL | ANSI/AAMI ES60601-1/60601-1-11 | UL62368 | |||||||||
CAN/CSA-C22.2 NO. 60601-1 | |||||||||||
TüV Rheinland/Mark | EN60601-1/EN60601-1-11 | - | |||||||||
TüV Rheinland/GS | - | EN62368-1 | |||||||||
CE | - | EN62368 | |||||||||
CCC | - | GB4943.1 | |||||||||
PSE | - | J62368 | |||||||||
KC | - | K60950-1 | |||||||||
RCM | - | AS/NES62368 |
Models & Ratings
Model Number | Voltage | Current | Rated Power | Ripple & Noise | Voltage Tolerance | Line & Load | Efficiency | Start Up Delay |
(V) | (A) | (max) | Regulation | |||||
UES24LCP1-XXXYYYSPA | 6.1-7.0 | 0.01-3.00 | 21W | 120mVpk-pk | ±5% | Line: ±1% Load: ±5% | 86.20% | ≤3s |
7.1-8.0 | 0.01-2.62 | 21W | 120mVpk-pk | ±5% | 86.20% | ≤3s | ||
8.1-9.0 | 0.01-2.33 | 21W | 150mVpk-pk | ±5% | 86.20% | ≤3s | ||
9.1-10.0 | 0.01-2.10 | 21W | 150mVpk-pk | ±5% | 86.20% | ≤3s | ||
10.1-11.0 | 0.01-2.18 | 24W | 150mVpk-pk | ±5% | 87.00% | ≤3s | ||
11.1-12.0 | 0.01-2.00 | 24W | 150mVpk-pk | ±5% | 87.00% | ≤3s | ||
12.1-13.0 | 0.01-1.84 | 24W | 200mVpk-pk | ±5% | 87.00% | ≤3s | ||
13.1-14.0 | 0.01-1.71 | 24W | 200mVpk-pk | ±5% | 87.00% | ≤3s | ||
14.1-15.0 | 0.01-1.60 | 24W | 200mVpk-pk | ±5% | 87.00% | ≤3s | ||
15.1-16.0 | 0.01-1.50 | 24W | 200mVpk-pk | ±5% | 87.00% | ≤3s | ||
16.1-17.0 | 0.01-1.41 | 24W | 200mVpk-pk | ±5% | 87.00% | ≤3s | ||
17.1-18.0 | 0.01-1.33 | 24W | 200mVpk-pk | ±5% | 87.00% | ≤3s | ||
18.1-19.0 | 0.01-1.26 | 24W | 200mVpk-pk | ±5% | 87.00% | ≤3s | ||
19.1-20.0 | 0.01-1.20 | 24W | 240mVpk-pk | ±5% | 87.00% | ≤3s | ||
20.1-21.0 | 0.01-1.14 | 24W | 240mVpk-pk | ±5% | 87.00% | ≤3s | ||
21.1-22.0 | 0.01-1.09 | 24W | 240mVpk-pk | ±5% | 87.00% | ≤3s | ||
22.0-23.0 | 0.01-1.04 | 24W | 240mVpk-pk | ±5% | 87.00% | ≤3s | ||
23.1-24.0 | 0.01-1.00 | 24W | 240mVpk-pk | ±5% | 87.00% | ≤3s | ||
45.1-46.0 | 0.01-0.52 | 24W | 300mVpk-pk | ±5% | 87.00% | ≤3s | ||
46.1-47.0 | 0.01-0.50 | 24W | 300mVpk-pk | ±5% | 87.00% | ≤3s | ||
47.1-48.0 | 0.01-0.49 | 24W | 300mVpk-pk | ±5% | 87.00% | ≤3s | ||
48.1-49.0 | 0.01-0.48 | 24W | 300mVpk-pk | ±5% | 87.00% | ≤3s | ||
49.1-50.0 | 0.01-0.47 | 24W | 300mVpk-pk | ±5% | 87.00% | ≤3s | ||
50.1-51.0 | 0.01-0.46 | 24W | 300mVpk-pk | ±5% | 87.00% | ≤3s | ||
51.1-52.0 | 0.01-0.51 | 24W | 300mVpk-pk | ±5% | 87.00% | ≤3s |